Begin Part Validation | AeccStructRectBoxCulvertHeadwall_Metric

Begin Part Family self validation test
ERROR: Required Parameter not found: Wall Thickness
ERROR: Required Parameter not found: Inner Pipe Diameter
ERROR: Parameter may be used more than once, index must be greater than zero: PDom (Catalog_Domain[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PTyp (Catalog_PartType[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PSTyp (Catalog_SubType[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PrtNm (Catalog_PartName[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PrtD (Catalog_PartDesc[0])
ERROR: Parameter may be used more than once, index must be greater than zero: DVer (DataVersion[0])
ERROR: Parameter may be used more than once, index must be greater than zero: CntTy (Content_Type[0])
ERROR: Parameter may be used more than once, index must be greater than zero: HPrtF (Catalog_PartHide[0])
ERROR: Parameter may be used more than once, index must be greater than zero: SBS (StructBoundingShape[0])
ERROR: Parameter may be used more than once, index must be greater than zero: CusSF (CustomPartSizing_Flag[0])
ERROR: Parameter may be used more than once, index must be greater than zero: SVPC (StructVertPipeClearance[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PrtSN (Catalog_PartSizeName[0])
ERROR: Parameter may be used more than once, index must be greater than zero: SBSL (StructLength[0])
OK: Part Domain parameter validated -- Structure_Domain
ERROR: Part Type parameter not validated
OK: Part Subtype parameter validated -- Undefined
OK: Part Description parameter validated -- Concrete Rectangular Box Culvert Headwall SI
OK: Part Name parameter validated -- AeccStructRectBoxCulvertHeadwall_Metric
OK: Part Size Name parameter found
OK: Unique Part Family ID  validated -- 1FCC7A73-9334-4BBB-967B-6A946EF5DC27
OK: Data Version parameter validated, version = 2.0
OK: Sample Expanded Table row successfully created
 
Begin Calc Usage Validation
OK: Calc Parameter PrtSN uses Context=Catalog_PartSizeName
OK: Calc Parameter LenA2 uses Context=Geometry_Distance2D
OK: Calc Parameter LenA4 uses Context=Geometry_Distance2D
OK: Calc Parameter LenA5 uses Context=Geometry_Distance2D
OK: Calc Parameter LenA6 uses Context=Geometry_Distance2D
OK: Calc Parameter LenA7 uses Context=Geometry_Distance2D
OK: Calc Parameter LenA8 uses Context=Geometry_Distance2D
OK: Calc Parameter SBSL uses Context=StructLength
OK: Calc Parameter SBSW uses Context=StructWidth
OK: Calc Parameter WPOf1 uses Context=Geometry_WorkplaneOffset
OK: Calc Parameter WPOf3 uses Context=Geometry_WorkplaneOffset
 
ERROR: Table Data Validation Failed | D:\OneDrive - APW Engineering\21-003 (MMCD DWT Update)\MMCD IDS (Autodesk Civil 3D 2022) Original\1_MMCD Civil 3D Standards\MMCD Pipes Catalog\Metric Structures\Inlet-Outlets\AeccStructRectBoxCulvertHeadwall_Metric.xml

ERROR: Part Validation Failed | Inlet-Outlets\AeccStructRectBoxCulvertHeadwall_Metric.xml